Only for solid nodules < 8 mm in diameter or 300 mm 3 or for nodules with < 10% risk of malignancy according to Brock model. Scroll down for the recommendation after the follow up scan.
What is the nodule volume (mm 3 )?:
What is the nodule diameter (mm):
Recommendation =
Insert the date in the following format: March 31, 2013
Date of 1st study:
Date of 2nd study:
Fill in either the diameter or volume measurements (not both). Use the diameter measurements if you do not have access to volume measurements.
Diameter at 1st study (mm):
Diameter at 2nd study (mm):
Volume at 1st study (mm 3 ):
Volume at 2nd study (mm 3 ):
Days between studies =
Volume doubling time (days) =
Warning: consider implications if volume doubling time >400 days and ≤600 days, where biospy may be appropriate rather than further CT. Additional warnings =
References
Page views:1197